身份证号码
#15660805
在露天场地
否
功能
Air Conditioner, Allison Automatic Transmission, 5551 hrs Carrier Engine, 2008 US EPA Label, Cummins QSX15 6 Cylinder 14.8 L Diesel Carrier Engine, Air Conditioner, Load Camera, Anti Two-Block, Grove/Integrated EKS5 Load Moment Indicator, 2008 US EPA Label, Cummins 6.7 L Diesel Upper Engine, 44 ft Minimum 223 ft Maximum Boom Length, 39 ft to 69 ft Bifold Swingaway Hydraulic Offset Jib, 1298 lb 20 ton Capacity Johnson 1 Sheave Hook Block, Overhaul Ball, 154000 lb Counterweight, Counterweight Removal System
General Appearance
(36)



































Serial Number / VIN
W092205308WG12079
CE Mark
No CE mark found
Hour Meter / Odometer
152875 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Operational, Some not operational, Right front house lights are not operational
Safety Certification Label
There is a safety certification label with a date of 09/16/2026
Safety Certification Report
Safety Certification Report Available
Load Chart
Yes
Safety
(9)








Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual
Control Station
(22)





















Lower/Carrier Engine Hours
5551 hrs Carrier Engine
Mirrors
Window Controls
Seats/armrests
Seat Belts
Operational
Steering Control
Horn
Operational
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational, Currently on its stabilizers
Gauges
Operational
Gear Selector
Brake Control
ECM Miles
Reader will not display ECM mileage
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.
Engine
(17)
















Emissions Status
2008 US EPA Label
Emission Label
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Diesel Particulate Filter
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.
Underbody
(48)















































Transmission
PTO Pump
Operational
Steer Axle
Front Drive Axle
Center Drive Axle
Rear Drive Axle
Final Drives
Limited Function Check - Carrier
The drivetrain was operational without a load.
Steering Linkage
Steering Wheel Play
Brake Type
Air
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Stopped the machine while rolling
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Springs/Hangers Condition
Frame Condition
Tire Condition
Wheel Condition
Wheel Studs
Hydraulics - Crane Carrier/Chassis
(6)





Pumps (Hydraulics)
Valves
There is fluid accumulation on valve body. No active drips were seen
Hydraulic Tank
Hoses (Hydraulic)
Stabilizer Cylinders
Limited Function Check
The hydraulic system was operational.
Upper Control Station
(18)

















Hour Meter Reading
14355 Hours-IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Seat Belts
Operational
Mirrors
Cab roof
Glass
Seats/Armrests
Horn
Operational
Safety Lock Out/Stop
Operational
Load Moment Indicator
Operational
Anti Two Block
Operational
Hydraulic Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises. Audible
Exterior Lights
Operational, Some not operational, Right front house lights are not operational
Warning Lights
Operational
Gauges
Operational
Drum Rotation Indicator
Operational
Air Conditioner
The ambient temperature is too cold to check.
Heater
Not operationally checked
Limited Function Check
The main components are in place and operational as noted.
Upper Engine
(13)












Emissions Status
2008 US EPA Label
Emission Certification Label
US EPA certification label
A/C Compressor
In place; ambient temperature too cold to check operation.
Blow by @ idle (subjective visual observation)
No noticeable vapor or pressure
Starter
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check (Engine)
The engine started and ran.
Chassis
(10)









Crane Superstructure
(23)






















Main Boom Pins
Main Boom Sections
Sheaves
Boom Head Section
Wear Pads
Turntable Bearing
Limited Function Check
The main crane components functioned when checked without a load.
Outrigger Beams
Outrigger Cylinders
Outrigger Pads
Crane Superstructure Hydraulics
(18)

















Pumps (Hydraulics)
Hydraulic Motors
Valves
There is fluid accumulation on valve body. No active drips were seen
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor
Main Hoist
Auxiliary Hoist
Untested
Lift Cylinders
Telescopic Boom Cylinders
No evidence of leaks
Limited Function Check
The hydraulic system was operational.
Specialty
(15)














Jib
Main Load Block
(2) Blocks supplied, (3) Sheave
Counterweights
Oil Sample Analysis
Oil Sample Analysis
| engine-1 | engine-2 | hydraulic-1 | transmission-2 | |
|---|---|---|---|---|
| Aluminum | 1.28 PPM | 1.84 PPM | 1.1 PPM | 3.67 PPM |
| Chromium | 0.77 PPM | 0.67 PPM | 2.03 PPM | 0.05 PPM |
| Copper | 0.43 PPM | 0.38 PPM | 8.86 PPM | 0.59 PPM |
| date of analysis | Oct 06, 2026 | Oct 06, 2026 | Oct 06, 2026 | Oct 06, 2026 |
| Iron | 25.62 PPM | 24.05 PPM | 4.06 PPM | 20.43 PPM |
| Lead | 2.38 PPM | 0.68 PPM | 4.68 PPM | 4.27 PPM |
| Nickel | 0.07 PPM | 0.09 PPM | 0.17 PPM | 0 PPM |
| Silicon | 6.46 PPM | 4.82 PPM | 17.77 PPM | 2.5 PPM |
| Silver | 0.02 PPM | 0.04 PPM | 0.04 PPM | 0.04 PPM |
| Tin | 0 PPM | 0 PPM | 0 PPM | 0.21 PPM |
附加信息
需要更多信息
customercare@ritchiebros.com
配送和提货
- 买家付清发票全款后,才会从拍卖场移除其所购之物。
- 司机必须携带利氏兄弟拍卖公司放行单的副本才能提货。
- 我们与值得信赖的配送供应商合作,让您以实惠的价格轻松找到优质运输商。您可以索取免费报价或从我们供应商的网站获取即时预估配送费用。
获取报价
借助 Ritchie Bros 的综合性服务门到门物流和配送解决方案,将您的设备送到所需之处。我们借助综合性服务,覆盖整个运输环节,确保您的设备经过边境、陆地及海洋,快速高效配送到您的手中。
一般信息
详细的设备信息范围有限,且除本文明确列出的方面或组件外,利氏兄弟拍卖公司并未检查设备中的任何其他方面或组件。除非另有明确声明,我们不会对设备或其组件作出任何形式的明示或暗示的陈述或保证。这包括但不限于关于功能、符合或遵循任何适用权力机构或监管机构的安全标准或要求、适用于任何特定用途,或者适销性的任何陈述或保证。我们强烈建议您在竞拍之前自行对设备进行详细检查。
功能
设备并未在负载条件下进行测试,也未在所有可用挡位下运行。我们不对设备运行符合制造商的规范作出任何声明或保证。除本文明确指出的功能外,我们未对任何其他功能方面进行任何检查。仅提供了各个底盘部件的部分照片,这些照片可能无法全面反映整个底盘的整体状况。